OpenTelemetry Bot d680729c09 [chore] Prepare release 0.90.0 (#29543) | пре 1 година | |
---|---|---|
.. | ||
internal | пре 1 година | |
testdata | пре 1 година | |
Makefile | пре 4 година | |
README.md | пре 1 година | |
client.go | пре 1 година | |
client_test.go | пре 1 година | |
config.go | пре 1 година | |
config.md | пре 1 година | |
config_test.go | пре 1 година | |
doc.go | пре 1 година | |
documentation.md | пре 1 година | |
factory.go | пре 1 година | |
go.mod | пре 1 година | |
go.sum | пре 1 година | |
info.go | пре 1 година | |
info_test.go | пре 1 година | |
integration_test.go | пре 1 година | |
keyspace.go | пре 1 година | |
keyspace_test.go | пре 1 година | |
latencystats.go | пре 1 година | |
latencystats_test.go | пре 1 година | |
metadata.yaml | пре 1 година | |
metric_functions.go | пре 1 година | |
metric_functions_test.go | пре 1 година | |
redis_scraper.go | пре 1 година | |
redis_scraper_test.go | пре 1 година | |
redis_svc.go | пре 1 година | |
redis_svc_test.go | пре 1 година |
Status | |
---|---|
Stability | beta: metrics |
Distributions | contrib, observiq, splunk, sumo |
Issues | |
Code Owners | @dmitryax, @hughesjj |
The Redis receiver is designed to retrieve Redis INFO data from a single Redis instance, build metrics from that data, and send them to the next consumer at a configurable interval.
The Redis INFO command returns information and statistics about a Redis server (see https://redis.io/commands/info for details). The Redis receiver extracts values from the result and converts them to open telemetry metrics. Details about the metrics produced by the Redis receiver can be found by browsing metric_functions.go.
For example, one of the fields returned by the Redis INFO command is
used_cpu_sys
which indicates the system CPU consumed by the Redis server,
expressed in seconds, since the start of the Redis instance.
The Redis receiver turns this data into a gauge...
func usedCPUSys() *redisMetric {
return &redisMetric{
key: "used_cpu_sys",
name: "redis.cpu.time",
units: "s",
mdType: metricspb.MetricDescriptor_GAUGE_DOUBLE,
labels: map[string]string{"state": "sys"},
}
}
with a metric name of redis.cpu.time
and a units value of s
(seconds).
:information_source: This receiver is in beta and configuration fields are subject to change.
The following settings are required:
endpoint
(no default): The hostname and port of the Redis instance,
separated by a colon.The following settings are optional:
collection_interval
(default = 10s
): This receiver runs on an interval.
Each time it runs, it queries Redis, creates metrics, and sends them to the
next consumer. The collection_interval
configuration option tells this
receiver the duration between runs. This value must be a string readable by
Golang's ParseDuration
function (example: 1h30m
). Valid time units are
ns
, us
(or µs
), ms
, s
, m
, h
.password
(no default): The password used to access the Redis instance;
must match the password specified in the requirepass
server configuration
option.transport
(default = tcp
) Defines the network to use for connecting to the server. Valid Values are tcp
or Unix
tls
:
insecure
(default = true): whether to disable client transport security for the exporter's connection.ca_file
: path to the CA cert. For a client this verifies the server certificate. Should only be used if insecure
is set to false.cert_file
: path to the TLS cert to use for TLS required connections. Should only be used if insecure
is set to false.key_file
: path to the TLS key to use for TLS required connections. Should only be used if insecure
is set to false.Example:
receivers:
redis:
endpoint: "localhost:6379"
collection_interval: 10s
password: ${env:REDIS_PASSWORD}
:information_source: As with all Open Telemetry configuration values, a reference to an environment variable is supported. For example, to pick up the value of an environment variable
REDIS_PASSWORD
, you could use a configuration like the following:
receivers:
redis:
endpoint: "localhost:6379"
collection_interval: 10s
password: ${env:REDIS_PASSWORD}
The full list of settings exposed for this receiver are documented here with detailed sample configurations here.